PGI Cobra BarriAire Gold Comprehensive Particulate Coverage Hood, w/ Extended Bib and Nano Flex Face Opening

PGI Fireline Wildland Fire Fighting
Write a Review

$140.26

You save: $21.26
MSRP: $161.52
SKU:
3979471-7
Internal ID:
619520
bisibi_enabled:
F
stock_status:
In Stock
clearance:
false
SKU: 3979471-7

Details

PGI BarriAire Gold Particulate Hood Comprehensive Coverage

Extended Bib with Nomex® Nano Flex Face Opening
Particulate coverage throughout entire head including Sure‑Fit™ panel at crown. Front and back bib extends particulate barrier coverage beyond critical areas as identified by NFPA – Maximum Protection. UL Classified to NFPA 1971 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting – Current Edition. Certification to the NFPA 1971, 2018 Edition Option for Particulate Protection – Current Edition.

Fabric Description:
Quilted composite durable water resistant finish on exterior layer of jersey knit with Nomex® Nano Flex particulate barrier between the inside layer of jersey knit. Averages 95%‑98% particulate filtration efficiency that actually improves with repeated launderings.
 
Fabric Performance Values Requirements for NFPA
1971 - 2018 Edition
PGI Test Results
Particulate Efficiency ≥ 90% 96%
Thermal Protective Performance (TPP)    
     Rib Knit    
  • As Recieved
  • After 5 Washings
20.0 (min)
20.0 (min)
30.2
33.1
     Quilted Composite    
  • As Recieved
  • After 5 Washings
20.0 (min)
20.0 (min)
29.3
30.8
Total Heal Loss (THL) ≥ 325 W/m2 401.3 W/m2
Hood Material Burst Strength > 225 N 614 N
Flame Resistance Test
Quilted Composite
   
     After Flame (Wales x Courses)    
  • As Recieved
  • After 5 Washings
≤ 2.0 sec
≤ 2.0 sec
0.0 sec x 1.0 sec
1.0 sec x 1.0 sec
     Char Length (Wales x Courses)    
  • As Recieved
  • After 5 Washings
≤ 100 mm
≤ 100 mm
18 mm x 17 mm
3 mm x 2 mm
Cleaning Shrinkage Resistance Test    
Hood Measurement    
  • After 5 Washings
 -5% -0.3%
Face Opening Measurement    
  • After 5 Washings
Meets Requirement YES
Heat & Thermal Shrinkage Resistance Test    
     Hood Measurement    
  • As Recieved
  • After 5 Washings
≥ -10%
≥ -10%
0%
0%
     Face Opening Measurement    
  • As Recieved
  • After 5 Washings
Meets Requirement
Meets Requirement
YES
YES
Seam Breaking Strength Test    
  • Quilted to Quilted
> 181 N 1064 N
Melt or Drop When Exposed to Flame No Melting or Dripping NONE